FireAlarm3D Learning Station
iOS Universel / Education
FireAlarm3D puts a complete 3-story commercial office building in your hands — every fire alarm and life safety system visible at once through transparent walls, interactive and explorable in full 3D.
Whether you are a fire alarm technician, AHJ inspector, sprinkler fitter, fire protection engineer, or student preparing for NICET certification, FireAlarm3D is the most comprehensive visual training reference available for NFPA 72 and NFPA 13 systems.
TAP ANY COMPONENT TO LEARN
Every device in the 3D scene is tappable. Tap a smoke detector, pull station, fire pump, or DACT/IP communicator and instantly see its NFPA code section, function description, inspection interval, common failure modes, and AHJ notes. Over 40 individually modeled devices — all interactive.
WHAT IS IN THE 3D BUILDING
Initiating Devices — smoke, heat (ROR and fixed-temp), manual pull stations, duct smoke, beam, flame (IR/UV), gas detectors (CO and NG)
Notification Appliances — horn/strobe units, mass notification speakers, visual appliances, fire phone jacks
Suppression — pendant and upright sprinklers, riser, fire pump, jockey pump, FDC, backflow preventer
Egress and Emergency — exit signs, emergency lighting, stairwell fans, elevator recall, HVAC air handling units
Control and Communications — FACP (UL 864), remote annunciator, DACT/IP communicator, SLC
Emergency Power — dedicated 120V AC primary supply, sealed lead-acid battery backup
SYSTEM FILTERS AND 3D WIRING
Toggle full system categories on and off to isolate any subsystem for study. Per-device-type toggles let you hide individual device types within each category. Enable the 3D wiring overlay to see color-coded SLC, NAC, and power conductors routed through the building. Zone highlighting (Z-1, Z-2, Z-3) dims all other zones so you can trace each zone's coverage independently.
LEARNING HUB — 6 TRAINING TOOLS
Quiz — NFPA 72 and NFPA 13 code questions on detector spacing, strobe candela, battery calculations, and more
Glossary — Over 30 terms defined: SLC, NAC, IDC, DACT, AHJ, T3 pattern, RTI, EOL resistor, supervising station, PSTN, IP communicator, and more
Guided Tour — 11-step Alarm Sequence of Events from detection through FACP processing, NAC activation, HVAC shutdown, elevator recall, DACT transmission, central station dispatch, and fire department arrival
Fault Simulator — open circuit on NAC, ground fault on SLC, smoke detector in alarm, sprinkler water flow
Load Calculator — battery standby and alarm load per NFPA 72 Annex B with 20% safety factor
Violations — common installation errors with code citations: detector spacing, strobe candela placement, beam obstruction, and more
ENGINEERING REFERENCE DOCUMENTS
Floor Plan — 3-floor device layout with zone boundaries and egress paths. Riser Diagram — fire alarm, sprinkler, and communication path (FACP to supervising station to fire department). Legend, Operation Matrix, Calculation Sheets, and Equipment Schedule included.
DESIGNED FOR THE FIELD
Dark charcoal interface with color-coded systems. Portrait and landscape on iPhone and iPad. All content works fully offline. Covers NFPA 72, NFPA 13, NFPA 20, NFPA 25, NFPA 92, IBC, ASME A17.1, UL 864, and UL 268.